Dry flow beverage coolers

Portable dry cooler for barreled beverages ANTA

Portable dry flow beverage cooler, for table placing, is made for tap a cool of barreled beverages.

The casing and the frame of Anta are made of stainless steel. For better manipulation are the handles placed on the the casing or they are ejecting on the sides. The machine controls are easily accesible on the back or in the height of taps.

The inputs placed on the back or in the middle of the bottom enables to connect the beverage and gas hoses from any direction.

Thermal exchanger is made of an aluminium block, which contains coils of stainless steel tubes with diameters 6,35 or 8mm. The horizontal organization of the cooling unit ensures efficient flow of intake air.

Dry tap device ANTA with ecological coolant R-134a meets the European standards for approval of product quality.

Units are produced even with inbuilt air compressor for pressuring the barrels.

To these products we hold certificates CE and TÜV.

Anta M24

Anta A40


Anta GK24
Anta M24 Anta A40 Anta GK24

Anta A Anta B Anta C

Technical parameters of dry coolers ANTA

Code Name Power. input
[W]
Δt 10°C
[l/h]
Air pump W
[kg]
Coils A  [mm] B
[mm]
C
[mm]
4901032 Anta
M24
150 24 no 19 1 235 275 375
4901033 Anta
MK24
150 24 yes 21 1 235 275 375
4901048 Anta
GK24
190 24 yes 25 1 340 420 420
4901003 Anta
A40
270 40 no 29 2 285 355 375
4901004 Anta
AK40
270 40 yes 31 2 285 355 375
4901002 Anta A1/5 270 32 no 27 1 360 280 350
4901001 Anta
AK1/5
270 32 yes 28 1 360 280 350
4901005 Anta
B 1/3
640 70 no 47 2 450 360 460
4901006 Anta
BK1/3
640 70 yes 48 2 450 360 460
4901007 Anta
B1/2
780 90 no 51 2 450 360 460
4901010 Anta
C5/8
850 120 no 62 2 510 480 480
4901011 Anta
C5/8
850 120 no 62 3 510 480 480

Handbill in PDF


Dry flow cooler ANTELAAntela

Portable dry flow beverage cooler, for table placing, is made for tap and cool of barreled beverages.

The casing and the frame are made of stainless steel with rounded corners and edges. The machine controls are easily accesible on the front panel.

The input is placed on the in the middle of the bottom enables to connect the beverage and gas hoses from any direction.

Thermal exchanger is made of an aluminium block, which contains coils of stainless steel tubes with diameters 6,35 or 8mm. The horizontal organization of the cooling unit ensures efficient flow of intake air.

Dry tap device ANTELA with ecological coolant R-134a meets European standards for approval of product quality.

Unit is produced even with inbuilt air compressor for pressuring the barrels.

Dry flow cooler Antela
Code Name Power input
[W]
Δt  10°C
[l/h]
Air pump W
[kg]
Coils A
[mm]
B
[mm]
C
[mm]
4906010 Antela 1/6-E1 260 27 no 28 1 430 340 240
4906011 Antela 1/6-EK1 260 27 yes 28 1 430 340 240

Scheme of coolers connection.
Handbill to download.